Produkte bis 55 Amps Produkte bis 55 Amps

Produktsuche


Steckverbinder bis 55 Amps


Up to
55 Amps
Primary Positions Signal Positions Connector Attributes
Amps (UL) (up to) Amps (CSA) (up to) Wire Sizes AWG  Wire Sizes mm² Quantity of Positions (up to) First Mate Ground Wire PCB Bus Bar Quantity
of
Positions
(up to)
Touch Safe Sealed Blind Mate
4 Position Solar
SPEC Pak® 
20 26 24 to 10 0.25 to 4.0 4 16
3 Pole Mini PL
SPEC Pak® 
22 16 24 to 12 0.25 to 2.5 3 *
5 Pole Mini PL
SPEC Pak® 
23 16 24 to 12 0.25 to 2.5 3 *
MARC Connector 29 29 20 to 10 0.25 to 6.0 8
PowerMod®  30 30 24 to 12 0.25 to 2.5 3 to 30 *
SAF-D-GRID,
AC 300 Volt
30 30 18 to 10 0.75 to 4.0 3
SAF-D-GRID,
DC 400 Volt 
30 30 18 to 10 0.75 to 4.0 
PP10 & PP30,
Pin & Socket 
30 30 16 to 10 1.3 to 5.3 1+
Power Drawer®
35 Amp 
35 35 16, 12 8.4, 2.5 8 21
4 Position
SPEC Pak® 
40 26 24 to 10 0.25 to 4.0 4 16
6 Position
SPEC Pak® 
45 29 24 to 10 0.25 to 4.0 6
Powerpole®
Blindmate
45 40 20 to 10 0.25 to 4.0 2 to 8
Powerpole® Pak 45 40 20 to 10 0.25 to 4.0 2 to 10
SBS™ Mini 52 35 20 to 10 0.25 to 4.0
Powerpole®
PP15 to 45 
55 40 20 to 10 0.25 to 6.0 1+
SBE® 80 /
SBO® 60 
80 80 16 to 4 1.3 to 25 2 8
Mid Power
SPEC Pak® 
80 50 12 to 6 2.5 to 13.3 4, 5 8
SBS®50  110 75 16 to 6 1.3 to 13.3 2
SBS®75G  110 75 16 to 6 1.3 to 13.3 3
SBS®75X  110 75 16 to 6 1.3 to 13.3 2 4
Powerpole® PP75  120 70 16 to 6 1.3 to 13.3 1+
SB®50  120 50 16 to 6 1.3 to 13.3 2



Note:

  • Amp ratings are stated per position and based on all positions being fully loaded.
  • Evaluate and test all connectors thoroughly to ensure they are appropriate for the specific applications.
  • UL amp rating:  Consult temperature rise charts for details.
  • CSA amp rating is based on a 30C rise.
  • Quantity of Position equal to "1+" signify that the parts are stackable.
  • Many of the mm² wire sizes are based on calculations. See the catalog for specific mm² wire sizes.