Steckverbinder von 150 Amps bis 250 Amps

150 Amps
up to
250 Amps
Primary PositionsSignal PositionsConnector
Attributes
Amps (UL) (up to)Amps (CSA) (up to)Wire Sizes AWG Wire Sizes mm²Quantity of Positions (up to)First Mate GroundWirePCBBus BarQuantity
of
Positions
(up to)
Touch SafeSealedBlind Mate
High Power SPEC Pak® (H06) 75 12 to 62.5 to 13.36  8  
DIN, E Series (E80) 160 8 to 210 to 352   4  
SBE®160 & SBX®175 17516010 to 1/05.3 to 53.52   8  
High Power SPEC Pak® (H03) 1901006 to 1/013.3 to 42.23   8  
Extreme SPEC Pak® (E04) 2001556 to 1/013.3 to 42.24   4  
Extreme SPEC Pak® (E04) 2001556 to 1/013.3 to 42.24   4  
DIN, E Series (E160) 2001606 to 1/016 to 502   4  
PowerMod® HP, Series A 2201306 to 213.3 to 351 to 2    
SB® Smart Connector230-10 to 1/05.3 to 53.52  16   
Powerpole® PP120 24011010 to 1/05.3 to 53.51       
SB®120 24013010 to 15.3 to 42.42     
High Power SPEC Pak® (H02) 2401406 to 3/013.3 to 852   8  
SB®175 28017510 to 1/05.3 to 53.32,3     
Power Clip®, Dual Pole (PCL03)300200n/an/a2      
Power Clip®, Single Pole (PCL01)300200n/an/a1      
Extreme SPEC Pak® (E02) 3102306 to 3/013.3 to 852      
SB® 2/034020001.02.00702       
Powerpole® PP180 35023010 to 3/05.3 to 851      
DIN, A Series (A320) 3502701/0 to 4/050 to 952   4  
DIN, E Series (E320) 3502601/0 to 4/050 to 952   4  
SBE® 320 / SBX® 350 3503201/0 to 300 mcm53.5 to 1522   8  
PowerMod® HP, Series B 4502501/0 to 4/053.5 to 951 to 2    

Note:

  • Amp ratings are stated per position and based on all positions being fully loaded.
  • Evaluate and test all connectors thoroughly to ensure they are appropriate for the specific applications.
  • UL amp rating:  Consult temperature rise charts for details.
  • CSA amp rating is based on a 30C rise.
  • Quantity of Position equal to "1+" signify that the parts are stackable.
  • Many of the mm² wire sizes are based on calculations. See the catalog for specific mm² wire sizes.