Connectors from 150 Amps to 250 Amps

150 Amps
up to
250 Amps
Primary Positions Signal Positions Connector
Attributes
Amps (UL) (up to) Amps (CSA) (up to) Wire Sizes AWG  Wire Sizes mm² Quantity of Positions (up to) First Mate Ground Wire PCB Bus Bar Quantity
of
Positions
(up to)
Touch Safe Sealed Blind Mate
High Power SPEC Pak® (H06)  75   12 to 6 2.5 to 13.3 6     8    
DIN, E Series (E80)  160   8 to 2 10 to 35 2       4    
SBE®160 & SBX®175  175 160 10 to 1/0 5.3 to 53.5 2       8    
High Power SPEC Pak® (H03)  190 100 6 to 1/0 13.3 to 42.2 3       8    
Extreme SPEC Pak® (E04)  200 155 6 to 1/0 13.3 to 42.2 4       4    
Extreme SPEC Pak® (E04)  200 155 6 to 1/0 13.3 to 42.2 4       4    
DIN, E Series (E160)  200 160 6 to 1/0 16 to 50 2       4    
PowerMod® HP, Series A  220 130 6 to 2 13.3 to 35 1 to 2        
SB® Smart Connector 230 - 10 to 1/0 5.3 to 53.5 2     16      
Powerpole® PP120  240 110 10 to 1/0 5.3 to 53.5 1              
SB®120  240 130 10 to 1 5.3 to 42.4 2          
High Power SPEC Pak® (H02)  240 140 6 to 3/0 13.3 to 85 2       8    
SB®175  280 175 10 to 1/0 5.3 to 53.3 2,3          
Power Clip®, Dual Pole (PCL03) 300 200 n/a n/a 2            
Power Clip®, Single Pole (PCL01) 300 200 n/a n/a 1            
Extreme SPEC Pak® (E02)  310 230 6 to 3/0 13.3 to 85 2            
SB® 2/0 340 200 01.02.00 70 2              
Powerpole® PP180  350 230 10 to 3/0 5.3 to 85 1            
DIN, A Series (A320)  350 270 1/0 to 4/0 50 to 95 2       4    
DIN, E Series (E320)  350 260 1/0 to 4/0 50 to 95 2       4    
SBE® 320 / SBX® 350  350 320 1/0 to 300 mcm 53.5 to 152 2       8    
PowerMod® HP, Series B  450 250 1/0 to 4/0 53.5 to 95 1 to 2        

Note:

  • Amp ratings are stated per position and based on all positions being fully loaded.
  • Evaluate and test all connectors thoroughly to ensure they are appropriate for the specific applications.
  • UL amp rating:  Consult temperature rise charts for details.
  • CSA amp rating is based on a 30C rise.
  • Quantity of Position equal to "1+" signify that the parts are stackable.
  • Many of the mm² wire sizes are based on calculations. See the catalog for specific mm² wire sizes.